website

Small Locking Plate

2.4/2.7 VA LCP Distal Palmar Radius Two-Column Locking Plate (head 6, 7holes)

Get In Touch With a Sales Consultant
Customized Products

Canwell’s 2.4/2.7 VA LCP Distal Palmar Radius Two-Column Locking Plate is a type of orthopedic implant used for the treatment of fractures or other injuries in the distal radius bone in the wrist. It has following features:

  1. Two-column locking plate: The plate has two columns of locking screws that provide improved stability and strength to the fracture site.
  2. Variable angle locking: The plate allows for variable angle locking of screws to accommodate different bone shapes and fracture patterns.
  3. Low profile: The plate has a low profile design that reduces soft tissue irritation and improves patient comfort.
  4. Anatomical shape: The plate is anatomically shaped to fit the contour of the distal radius bone for optimal fixation.
  5. Titanium construction: The plate is made of titanium, a material that is biocompatible and strong.

Canwell’s 2.4/2.7 VA LCP Distal Palmar Radius Two-Column Locking Plate is considered better than other brands’ same product because of its UNIQUE DESIGN FEATURES that improve its strength, stability, and comfort. The two-column locking system and variable angle locking allow for more secure fixation and better adaptation to different bone shapes and fracture patterns. The low profile and anatomical shape reduce soft tissue irritation and improve patient comfort, which can lead to better outcomes and faster recovery times. Additionally, the use of titanium as the construction material provides strength and biocompatibility, reducing the risk of complications or adverse reactions.

Overall, Canwell’s 2.4/2.7 VA LCP Distal Palmar Radius Two-Column Locking Plate is a high-quality orthopedic implant that offers numerous advantages over other brands’ similar products.

CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
4Holes 66mm Left Ti PC 122323104
CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
5Holes 75mm Left Ti PC 122323105
CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
2Holes 45mm Right Ti PC 122323202
CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
3Holes 54mm Right Ti PC 122323203
CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
4Holes 66mm Right Ti PC 122323204
CanVLP VA LCP Distal Palmar Radius two-column Locking Plate
(Head 6 Holes)
5Holes 75mm Right Ti PC 122323205
Material

Titanium

specification

Name SPEC1 SPEC2 Direction
Head 6 holes 2Holes 45mm Left
Head 6 holes 3Holes 54mm Left
Head 6 holes 4Holes 66mm Left
Head 6 holes 5Holes 75mm Left
Head 6 holes 2Holes 45mm Right
Head 6 holes 3Holes 54mm Right
Head 6 holes 4Holes 66mm Right
Head 6 holes 5Holes 75mm Right
Head 7 holes 2Holes 47mm Left
Head 7 holes 3Holes 55mm Left
Head 7 holes 4Holes 68mm Left
Head 7 holes 5Holes 77mm Left
Head 7 holes 7Holes 95mm Left
Head 7 holes 9Holes 113mm Left
Head 7 holes 11Holes 131mm Left
Head 7 holes 2Holes 47mm Right
Head 7 holes 3Holes 55mm Right
Head 7 holes 4Holes 68mm Right
Head 7 holes 5Holes 77mm Right
Head 7 holes 7Holes 95mm Right
Head 7 holes 9Holes 113mm Right
Head 7 holes 11Holes 131mm Right

Scroll to Top